Product images are for illustration purposes only. Please review specifications and documentation for exact product details.
AF26Z-30-00-23 ABB Contactors, AF Series
Specifications
| Manufacturer Part Number | AF26Z-30-00-23 |
|---|---|
| Manufacturer | ABB |
| Product Series | AF |
| Family Series | ABB Contactors, AF Series |
| Type | AC Non-Reversing IEC |
| Nominal Coil Voltage | 120 VAC, 208 VAC, 240 VAC, 125 VDC, 250 VDC |
| Coil Voltage | 100-250 VAC, 100-250 VDC |
| Coil Type | Electronic |
| Poles | 3NO |
| Auxiliary Contact | None |
| Termination | Screw |
| General Purpose (AC1) | 45 A |
| UL Motor Switching (AC3) | 26 A |
| Approvals | cULus |
| H x W x D | 1.85 " x 3.43 " x 3.43 " |
| Net Weight | 0.775 lbs |
| Gross Weight | 0.81 lbs |
Description
AF Series Information
- Coils Cover 24 V ‑ 500 V AC and 20 V ‑ 500 V DC
- 24 V DC Coil for Direct Control by PLC‑Output > 250 mA
- Low Holding Consumption up to 1.7 W
- Mirror, Mechanically Linked Contacts
- Built‑in Surge Suppression
- Up to 560 kW ‑ 400 V AC‑3, 900 hp ‑ 480 V and 2850 A ‑ 690 V AC‑1, 2850 A ‑ General Use
The AF Series of contactors are used for controlling power circuits up to 600 V AC and 240 V DC. They are mainly used for controlling 3‑phase motors, non‑inductive or slightly inductive loads. Contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC – AF contactors can manage large control voltage variations. One coil (e.g., 100...250 V 50/60 Hz ‑ DC) can be used for different control voltages used worldwide without any coil change – AF contactors have built‑in surge protection and do not require additional surge suppressors – The built‑in N.C. auxiliary contact is a mirror contact in compliance with annex F of IEC 60947‑4‑1.
Contactors contain integrated, electronically controlled coils which reduce energy consumption. Contains push‑in spring terminals which allow for fast, easy wiring. Contactors can overbridge voltage drops and sags.
Documents & Resources Links
Videos
Accessories
Compare compatible accessories for this product.
| Image | Part | Description | Series | Type | Price | Action |
|---|---|---|---|---|---|---|
|
BER38-4 | BER and BEM connection sets are insulated and made of solid copper bars. |
Price unavailable
|
|||
|
CA4-01 | For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function | Auxiliary Contact Block |
Price unavailable
|
||
|
CA4-10 | For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function | Auxiliary Contact |
Price unavailable
|
||
|
CAL4-11 | For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function | Auxiliary Contact |
Price unavailable
|
||
|
TF42-0.13 | The TF42-0.13 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.17 | The TF42-0.17 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.23 | The TF42-0.23 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.31 | The TF42-0.31 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.41 | The TF42-0.41 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.55 | The TF42-0.55 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-0.74 | The TF42-0.74 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-1.0 | The TF42-1.0 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-1.3 | The TF42-1.3 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-1.7 | The TF42-1.7 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-2.3 | The TF42-2.3 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-3.1 | The TF42-3.1 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-4.2 | The TF42-4.2 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-5.7 | The TF42-5.7 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
TF42-7.6 | The TF42-7.6 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features | TF42 | Bimetallic |
Price unavailable
|
|
|
VEM4 | Mechanical and Electrical Interlock, Includes 2-N/C Aux Circuits, BB4 Fixing Clips Also Included | Interlock |
Price unavailable
|